Interact CardioVasc Thorac Surg 2006;5:279-281. doi:10.1510/icvts.2005.123125 © 2006 European Association of Cardio-Thoracic Surgery
A new exposure technique for the circumflex coronary artery system in robotic totally endoscopic coronary artery bypass graftingDepartment of Cardiac Surgery, Innsbruck Medical University, Anichstrasse 35, A-6020, Innsbruck, Austria
*Corresponding author. Tel.: +43 512 504 80631. We report a case of a 53-year-old female patient with isolated left main coronary artery stenosis in whom a completely endoscopic double coronary artery bypass grafting (CABG) procedure was performed. The operation was carried out on the arrested heart. A right internal mammary artery graft was sutured to the left anterior descending artery using the daVinciTM telemanipulation system. The left internal mammary artery was connected to the first obtuse marginal branch which was exposed with the Octopus-TETM stabilizing device. This method may be useful for further development of multivessel totally endoscopic CABG procedures.
Key Words: Coronary artery bypass grafting; Endoscopic surgery; Robotic surgery; Left main coronary artery stenosis This article has been cited by other articles:
|
||||||||||||||