ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Interact CardioVasc Thorac Surg 2007;6:462-469. doi:10.1510/icvts.2006.145532
© 2007 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Rafael García Fuster
Ignacio Rodríguez
Sergio Cánovas
Oscar Gil
Fernando Hornero
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by García Fuster, R.
Right arrow Articles by Martínez-León, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by García Fuster, R.
Right arrow Articles by Martínez-León, J.
Related Collections
Right arrow Valve disease

Institutional report - Valves

Prosthesis–patient mismatch with latest generation supra-annular prostheses. The beginning of the end?{star}

Rafael García Fuster*, Vanesa Estevez, Ignacio Rodríguez, Sergio Cánovas, Oscar Gil, Fernando Hornero and Juan Martínez-León

University General Hospital of Valencia, Valencia, Spain

*Corresponding author. C/Artes Gráficas n°4, esc. izq. pta.3, 46010 Valencia, Spain. Tel.: +34 96 3622216; fax: +34 96 1972163.

E-mail address: rgfuster{at}terra.com (R. García Fuster).

Most studies about prosthesis–patient mismatch (PPM) were conducted before the introduction of new high-performance prostheses. Nowadays, PPM could become unfrequent. Our aim was to study the impact of new prostheses on PPM in comparison with previous experience. Prosthetic Indexed Effective Orifice Area (EOAi) was estimated in two historical cohorts. Group A: 339 patients undergoing AVR from Mar 94–Nov 01. Group B: 404 operated on during the last three years when latest generation prostheses were implanted. Incidence, determinants of PPM and clinical results were studied. Moderate PPM (EOAi ≤0.85 cm2/m2) was present in 38% and 19% (respective groups). Mean EOAi increased from 1.02±0.29 cm2/m2 to 1.11±0.27 cm2/m2. ‘Group B’ and ‘new prostheses’ were protective. Thirty-day mortality was 3.8% and 4.7% with higher rate in patients with increased left ventricular mass index (LVMI), especially if PPM was present: 14.7 vs. 2.1% (P<0.05) in Group A; 25.0 vs. 4.8% (P<0.05) in Group B (PPM vs. no-PPM). LVMI regression was impaired in these patients. Moderate PPM was an independent predictor of late cardiac mortality (OR: 3.38, 95% CI: 1.37–8.31; P<0.01). PPM is a prognostic factor for late cardiac death. Its impact on early mortality is only relevant in patients with high LVMI. Its incidence has decreased with the use of new prostheses.

Key Words: Prosthesis–patient mismatch; Aortic valve replacement; Mortality




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
S. Nozohoor, J. Nilsson, C. Luhrs, A. Roijer, and J. Sjogren
Influence of Prosthesis-Patient Mismatch on Diastolic Heart Failure After Aortic Valve Replacement
Ann. Thorac. Surg., April 1, 2008; 85(4): 1310 - 1317.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 European Association for Cardio-thoracic Surgery