ICVTS Click here to goto Smart Canula website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published on June 23, 2008
Interactive CardioVascular and Thoracic Surgery 2008, doi:10.1510/icvts.2008.175281
© 2008 European Association of Cardio-Thoracic Surgery

This Article
Right arrow Full Text (Journal Format PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me when eComments are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Pai, K. R.
Right arrow Articles by Dihmis, W. C.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pai, K. R.
Right arrow Articles by Dihmis, W. C.
Related Collections
Right arrow Great vessels

Cardiac general

Phenoxybenzamine treatment can lead to loss of endothelial cell viability

Krishnanand R. Pai 1, Alan Conant 2*, Paul G. Browning 2, Walid C. Dihmis 2

1 Birmingham Heartlands Hospital, UK
2 The Cardiothoracic Centre, Liverpool NHS Trust, UK

* To whom correspondence should be addressed. E-mail: conant{at}liv.ac.uk.


   Abstract
Phenoxybenzamine, an irreversible {alpha}-adrenoceptor antagonist, is used as a topical treatment against catecholamine-induced contraction in radial artery bypass grafts. Published data suggests that a wide range of phenoxybenzamine doses may be equally effective. This study aimed to investigate whether lower doses of phenoxybenzamine would benefit grafts by better preserving endothelium. To this end human vascular endothelial cells were isolated from sections of radial artery or saphenous vein, and treated with phenoxybenzamine for 30 min. Cells were then washed free of drug and viability assayed using a resazurin-based toxicology assay or returned to culture for assay at 24 h. Phenoxybenzamine treatment showed a dose-dependent, effect on cell viability over several clinically employed concentrations. Concentrations above 0.1 mM led to a loss of viability, which became more pronounced with time. The loss of viability was shown to be independent of the carrier used, as results were identical when phenoxybenzamine was dissolved in dimethylsulphoxide, which alone did not affect viability. Changes in pH alone were also not sufficient to affect viability. In conclusion, phenoxybenzamine treatment is likely to cause damage to graft endothelium if employed at concentrations above 0.1 mM (0.03 mg/ml). Phenoxybenzamine may be safely used at lower doses with no potential loss of endothelial cell viability. Keywords: Coronary artery bypass conduits; Arteries; Endothelium; Vasodilators; Viability